Menu

Cryometrix L-80 Liquid Chiller

Utilizing liquid nitrogen, the L-80 is the fastest ethanol chiller on the market.

Capable of chilling 120 gallons of Ethanol to -65 °C in 60 minutes and to -45 °C in 45 minutes, the L-80 is the most powerful yet price-efficient tool for chilling solvents. Featuring patent-pending technology, the L-80 is specifically designed to work with liquids like ethyl alcohol for CBD extraction and winterization. Use our L-80 as a cannabinoid chiller for your process!

The L-80 is portable, requires zero changes to your build's infrastructure and has a low power requirement of 110 volts, enabling it to be implemented in any facility. With practically silent operation, the L-80 Liquid Chiller is ideal for chilling solvents or other liquids used in a lab, small manufacturing processes, or large-scale production facilities.

Cryometrix Liquid Nitrogen Technology is patented and patent pending.

External Dimensions
(Depth x Width x Height) 1016 mm x 1219 mm x 1676 mm 40" x 48" x 66"

Barrel Dimensions
(Diameter x Height) 762 mm x 1168 mm 30" x 46"

Barrel Capacity 454 liters 120 gallons

Temperature Range 20°C to -80°C 68°F to -112°F

Peak Variation from Setpoint 1°C ± 1.8 °F ±

120 gal Ethanol Pull Down
-65°C (-85°F) 60 minutes

120 gal Ethanol Pull Down
-40°C (-40°F) 45 minutes

Fill Time 6 minutes

Drain Time (@ -65°C)12 minutes

LN2 Consumption / Cycle283 L 75 gal

LN2 Usage / Gal Ethanol Chilled 2.2 L / 1 gal 0.6 gal / 1 gal

Applications

CBD Extraction Chiller

A common type of CBD extraction uses ethanol to extract useful cannabinoids. The warmer the ethanol, the more unwanted plant particulates are also extracted. Because of this, chilling the ethanol increases extracted Cannabinoid purity.

CBD Oil Winterization

Oil extracts tend to have plant material intermixed within them after extraction, including CO2 Hemp Extraction. The L-80 proves a powerful tool for extract winterization.

Research

Liquid chillers are typically large, bulky, and expensive, requiring large budgets for any research that required them. The L-80 allows for smaller, sleeker, and cheaper chilling of liquids used for research.

Manufacturing

The L-80 is suited for small operations or large scale industrial production.

Key Features

Automatic Fill Stop

The L-80 will automatically stop pumping from the bulk liquid supply once the top fill level is reached.

Automatic Drain Stop

The L-80 will automatically stop pumping liquid out of the chilling chamber once the low level is reached.

Datalogging

The L-80 constantly logs liquid temperature, LN2 pressure, and pump load.

Food Grade Stainless Steel

The liquid being chilled within the L-80 only comes into contact with food-grade stainless steel.

Zero Workspace Modification

The L-80 is small and portable, fitting into any workspace and can be moved with a pallet jack.

Running on 110v, the L-80 can plug into common outlets.

Zero heat is rejected into the room, so no HVAC is required.

Benefits over Compressor-Based Liquid Chillers

Less Maintenance

Unlike compressor-based chillers which have hundreds of moving parts, the L-80 has only a few moving parts, so very little maintenance is required.

Reduced Electric Power Usage

You will not need to run any power to your building when running our chiller.

Faster Chilling and Better Performance

The low temperature of LN2 enables the L-80 to chill rapidly and to lower temperatures.

Complete Safety

Closed Nitrogen System

There is zero contact between LN2 and the operator or product.

LN2 storage is simple and completely autonomous.

Unreactive

Nitrogen isn't flammable or explosive like many refrigerants used in compressor-based technologies.

Easy Cleaning

The 100% stainless steel design is easy to clean without harsh industrial chemicals.

Environment Friendly

Clean Emissions

Cryometrix products only emit nitrogen outside your building, which already makes up over 75% of the Earth's atmosphere.

Powerful Innovation

Next-Gen Liquid Nitrogen Tech

Cryometrix products don't use traditional mechanical compressors that utilize refrigerants, an example being freon, to produce cold temperatures. These are noisy and use large amounts of electricity.

LN2 has a boiling point of -196°C, enabling temperatures as low as -196°C. Most refrigerants have boiling points greater than -100°C, making it difficult for technology that uses them to generate temperatures below that.

Low Energy Usage

Cryometrix tech use 7x less electricity than comparable products.

LN2 operates on pressure and requires no electricity to function, enabling it to function without power in emergency situations.

Extreme Reliability

Cryometrix freezing technology doesn't require HVAC systems to cool the ambient temperature in order to operate. It can operate in any ambiance and cools the environment around it.

There are practically no moving parts in Cryometrix LN2 freezing technology, making it last up to 4 times as long as comparable freezing technology, in addition to requiring hardly any maintenance.

Practically silent when in operation.

Easily Expandable

Cryometrix products consume little electricity, enabling the customer to add additional units to their facility with zero electrical complications.

The effective footprint is 16 square feet and little to no space is needed on the sides, easily fitting into any facility.

Extreme Versatility

The L-80 can chill any liquid that can handle the ultra-low temperatures at which it operates.

Cost Efficiency

Space Efficient

The Cryometrix L-80 Solvent Chiller has the smallest footprint for its liquid chilling capability, costing less in floor space and allowing you to fit more units in your current space.

Simple Design

The simple functioning and operation of the L-80 doesn't require extensive training, reducing labor costs and risks.

Low Energy Costs

LN2 technology uses much less electricity than traditional compressor-based technologies.

Cryometrix products don't need energy intensive HVAC systems to operate efficiently.

Greater Throughput

The increased capability of the L-80 allows faster turnaround times and thus greater profits.

Sample Integrity

Closed System

No LN2 is exposed to the sample, maintaining the samples integrity.

Data-Logging

The L-80 automatically tracks temperature and other useful data.

Temperature Uniformity

A pump maintains high flux throughout chilled liquid, maintaining even temperatures throughout.

70.4054054054054
148

Customer Reviews

Pages

Have You Used This Product?

Harvest Headquarters & Glass Gallery

Born in Humboldt